Overview
The LW35-126 is a three-pole, outdoor, AC high-voltage SF₆ circuit breaker designed for 50Hz power transmission and distribution systems. It is used for making and breaking rated currents, fault currents, and for line switching to provide protection, control, and operation of the system. The breaker is capable of three-pole opening, closing, and high-speed auto-reclosing operations.
Featuring advanced design principles, it offers a simple structure, compact size, reduced material usage, low required operating energy, high reliability, easy installation, and low noise levels. It represents a new generation of high-voltage SF₆ circuit breakers.
Normal Service Conditions
Ambient Temperature: -30°C to +40°C
Wind Pressure: ≤ 700 Pa (corresponding to a wind speed of 34 m/s)
Altitude: ≤ 3000 m above sea level
Seismic Intensity: ≤ 9 degrees
Air Pollution Severity: Class III
Technical Specifications
|
S.Q. |
Insulation Level |
LW35-126 |
|
|
1 |
Power-Frequency Withstand Voltage (1 min, r.m.s., Dry & Wet) |
Across Contacts (Pole Spacing) |
294 |
|
Across Poles or Between Pole and Earth |
294 |
||
|
2 |
Lightning Impulse Withstand Voltage (Full Wave, 1.2/50 μs, Peak) |
Across Contacts (Pole Spacing) |
703 |
|
Across Poles or Between Pole and Earth |
703 |
||
|
3 |
Power-Frequency Withstand Voltage (5 min, r.m.s.) at Zero Gauge SF₆ Gas Pressure |
Between Contacts (Open) |
95 |
|
Between Pole and Earth |
95 |
||
|
S.Q. |
Name |
Unit |
Data |
|
1 |
Rated Voltage |
kV |
126 |
|
2 |
Rated Current |
A |
3150 |
|
3 |
Rated Short-Circuit Breaking Current |
kA |
31.5/40 |
|
4 |
Rated Short-Time Withstand Current |
kA |
40 |
|
5 |
Rated Peak Withstand Current |
kA |
100 |
|
6 |
Rated Duration of Short-Circuit |
S |
3 |
|
7 |
Rated Short-Time Duration |
kA |
100 |
|
8 |
Rated Short-Circuit Making Current (Peak) |
kA |
28.5/23.6:36/31.5 |
|
9 |
Rated Short-Line (Near-to-Generator) Fault Breaking Current |
kA |
31.5 |
|
10 |
Rated Line-Charging Breaking Current |
A |
8 |
|
11 |
Rated Out-of-Phase Breaking Current |
kA |
12 |
|
12 |
Cumulative Breaking Operations at Rated Short-Circuit Breaking Current |
times |
1.5 |
|
13 |
First-Pole-to-Clear Factor |
Open - 0.3s - Close-Open - 180s - Close-Open |
|
|
14 |
Rated Operating Sequence |
≤45 |
|
|
15 |
Rated Main Circuit Resistance |
μΩ |
3000 |
|
16 |
Circuit Breaker Mechanical Endurance |
times |
≤1% |
|
17 |
SF6 Gas Annual Leakage Rate |
≤150 |
|
|
18 |
SF6 Gas Moisture Content (V/V) |
ppm |
150±4 |
|
19 |
Contact Travel |
mm |
25±3 |
|
20 |
Contact Over-Travel |
mm |
Hot Tags: lw35-126 series outdoor high voltage sf6 circuit breaker, China lw35-126 series outdoor high voltage sf6 circuit breaker manufacturers, suppliers, factory, LW35 126 Series Outdoor High Voltage SF6 Circuit Breaker, sulfur hexafluoride sf6 circuit breaker, LW24 40 5 Series High Voltage SF6 Circuit Breaker, LW30 126 Series High Voltage SF6 Circuit Breaker, LW 252 Series Outdoor High Voltage SF6 Circuit Breaker, LW30 72 5 Series High Voltage SF6 Circuit Breaker