Your Leading Load Break Switch Supplier

 

Trust In Grid Co., Ltd. is a professional transformer manufacturer, specializing in the design and production of power transformer, high-voltage switchgear, power distribution equipment, energy storage systems (ESS), magnetic wire, bushing and machining parts. Our power transformers are available in 500KV, 330KV, 220KV, and 110KV models, and are widely used in power utilities, renewable energy systems (solar and wind), industrial facilities, data centers, transportation infrastructure, and OEM applications.

 

 
 
Why Choose Us?

 

Production Capacity

With 6 factories covering 240,000 m², over 2,000 employees, and 200+ engineers, we support large-scale projects and long-term global supply with more than 30 years of export experience.

Advanced Equipment

We operate a complete set of in-house production equipment, including cutting, winding, CNC machining, vacuum drying, and testing systems, with over 450 machines ensuring stable quality and efficient output.

Quality Control

All products are manufactured and tested in compliance with IEC, IEEE, ANSI, CSA, UL/cUL, CE, and ISO 9001:2015 standards, ensuring reliable performance and smooth international approval.

OEM & ODM Capability

Our engineering team provides OEM/ODM support, including customized design and technical optimization, delivering tailored solutions for utility, industrial, and renewable energy projects.

 

Technical Specifications of Load Break Switch

 

S.Q.

Item

Unit

Parameter

1

Rated Voltage

KV

12

24

40.5

2

Rated Frequency

Hz

50/60

50/60

50/60

3

Rated Insulation Level (at filled SF6 gas pressure 0.07 MPa / 20°C)

Lightning Impulse Withstand Voltage

Between phases, Phase-to-earth

KV

75

125

185

Interrupter unit gap

85

145

215

Power Frequency Withstand Voltage (1 min)

Between phases, Phase-to-earth

42

64

95

Interrupter unit gap

50

79

110

4

Insulation Level at Zero Gauge Pressure

Power Frequency Withstand Voltage (1 min)

KV

30

Power Frequency Withstand Voltage (1 min) Reverse Polarity

30

Highest Phase Voltage (5 min) Between Phases and Phase-to-earth

9

5

Rated Current

A

630

630

630

6

Rated Load Breaking Current (at 0.07 MPa / 20°C)

A

630

630

630

 

FKRN12A-12 Series 12kV Indoor Gas-Insulated Load Break Switch

 

Advantages of Load Break Switch

Cheaper As Compared To 2 Pole Structure
Regardless of the technology used in a load break switch, its installation and acquisition cost is far lower than a 2-pole structure. However, its price depends on the power source, IP rating, voltage/power, frequency, and current rating. The LBS' s convenient use and reasonable prices make it widely used in distribution network systems of about 10kV.

 

Safer
A load break switch is mainly used to close and break the load current and can be used with a high-voltage fuse instead of a circuit breaker. The reasonable selection of load balancing switch in the design dramatically helps ensure safety and reliability. As a result, the dangers associated with tripping circuit breakers are eliminated, providing a safer power grid operation.

 

Provided With Fuse Protection
Load break switches also feature HRC fuses for transformer protection, ensuring more safety and reliable operation. However, you also can use a vacuum circuit breaker, although it is a bit costlier and more reliable.

In addition, the transmission lines are protected from overheating, leading to fires, while the appliances like transformers are protected from the damages that might be caused by short-circuiting or catching fires.

 

Turning The Power Supply On & Off Is Easy
Load break switches usually feature a spring mechanism for switching the power supply on or off. This makes the process of turning the power supply on or off easier.

 

Applications of a Load Break Switch

 

 

To begin with, a load break switch (LBS) manages equipment in medium voltage electrical systems, usually ranging from 11kV to 33kV. You know it has a small size, but it performs amazing functions in assuring the continual and secure delivery of power. Let' s talk about some core purposes of a load-reaction switch.

 

Safe Control Of Power Flow
As we already discussed, one of the most important objectives of a load break switch is to manage the flow of electric current. It lets power be switched on or off at one part of the whole system. So, this helps maintain smooth operational flow while providing control over selected sub-systems or areas of the power line.

 

Easy and Safe Isolation
Well, another major function is isolation. Yes, if there is any fault in any part of the system, it will disconnect the power to that particular section. Therefore, it enhances the safety of workers as the power has been cut off. Moreover, this enhances safety against electric shocks or accidents.

 

Helps During Maintenance
During upgrades or during regular maintenance, the load break switches help in isolating the section of the circuit. As a result, a safe environment is created for workers. Moreover, it is easy to operate the switch as it does not require any special tools.

 

Useful in Emergency Situations
Unlike other load break switches, these can now be operated remotely. Such a feature is more helpful in emergencies or bad weather. However, Operators can remove power from a safe distance efficiently, which prevents them from any harm.

 

Keeps the System Stable
Moreover, the use of these LBS devices helps prevent drastic changes in power flow. This avoids damage to electrical equipment and makes sure the network stays running properly.

 

Ordering Process

 

Send Us Inquiry → Receive Our Quotation → Negotiate Details → Confirm the Sample → Sign Contract/Deposit → Mass Production →Cargo Ready → Balance/Delivery → Further Cooperation 

 

Customization Options
 

Material: Customizable

Logo: Customizable

Structure: Customizable

MOQ: Customizable

 

The Difference Between a Load Break Switch and an Isolating Switch

 

Feature

Load Break Switch (LBS)

Disconnect Switch (Isolator)

Functionality

Makes and breaks current under normal load

Isolates a circuit, creating a visible air gap

Interrupting Capability

Yes, can safely interrupt load current

No, must not be operated under load

Arc Extinguishing

Equipped with arc quenching mechanisms (e.g., SF6, vacuum)

No arc extinguishing capability

Contact Design

Robust, designed for arc withstand and quenching

Simpler, designed for secure open circuit

Operating Mechanism

Often quick-break for rapid interruption

Slower, deliberate operation for isolation

Primary Application

Switching under load, sectionalizing networks

Providing safe isolation for maintenance and lockout/tagout

 

Payment Terms
 

T.T with 30% downpayment, 70%before shipment.

Paypal or West Union also accept.

 

 

Our Service Highlights

 

 

Pre-Sales Consultation & Design Support
Early technical engagement to define requirements and deliver optimized solutions.

 

During Sales & Project Execution
Transparent project management with controlled production, quality tracking, and on-time delivery.

 

Warranty Advantage
Minimum 2-year warranty on all products, ensuring reliable and risk-free operation.

 

After-Sales Support
24/7 technical support with fast response, spare parts availability, and training services.

 

Long-Term Partnership
Lifelong technical support and upgrade guidance for sustained performance.

 

Packaging & Shipping

 

Packaging details:
Shockproof foam/moisture-proof film, professional export cartons/wooden crates/pallets.
Final assembly ensures mechanical integrity and readiness for transportation and installation. 

 

productcate-808-351

 

Certificates

 

 

productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1

 

FAQ

 

Q: What is a load break switch (LBS)?

A: A load break switch is a medium-voltage switching device used to safely make or break normal load current in a circuit. It is commonly used in distribution networks for switching and control operations.

Q: What is the main function of a load break switch?

A: Its main function is to switch electrical circuits under normal operating load conditions. It allows operators to isolate or connect feeders safely without interrupting system stability.

Q: Where are load break switches typically used?

A: They are widely used in substations, ring main units (RMUs), industrial power systems, and utility distribution grids. They are especially common in medium-voltage networks.

Q: Can a load break switch interrupt short-circuit faults?

A: No, it is not designed to clear fault currents. Fault protection is handled by circuit breakers or protection relays in the system.

Q: What is the difference between a load break switch ana circuit breaker?

A: A load break switch operates under normal load conditions, while a circuit breaker can interrupt both load and fault currents. This makes circuit breakers suitable for system protection.

Q: What is the difference between a load break switch and a disconnector?

A: A disconnector only provides isolation and must be operated when the circuit is de-energized, while a load break switch can safely switch current under normal load conditions.

Q: What standards apply to load break switches?

A: They are generally designed according to IEC 62271 standards, which define performance, insulation, and safety requirements for medium-voltage switchgear.

Q: Do load break switches require maintenance?

A: Yes, periodic inspection of contacts, mechanical operation, and insulation condition is recommended to ensure long-term reliability and safe switching performance.

We're well-known as one of the leading load break switch manufacturers and suppliers in China, also support customized service. Please feel free to buy high quality load break switch made in China here from our factory. Contact us for more details.

FZW32 12 40 5kV Series Outdoor High Voltage Vacuum Isolating Load Break Switch, medium voltage load interrupter switch, FZRN25 12D Series Vacuum Isolating Load Break Switch Fuse Combination Unit