110kV Oil-Immersed 3-Phase 2-Winding OLTC Power Transformer
video
110kV Oil-Immersed 3-Phase 2-Winding OLTC Power Transformer

110kV Oil-Immersed 3-Phase 2-Winding OLTC Power Transformer

110kV Oil-Immersed 3-Phase 2-Winding OLTC Transformer.

Intelligent voltage-regulating solution for critical 110kV grid nodes.

Rated 6.3 to 63 MVA, HV 110kV, LV 6.3-21kV.

Features ±8×1.25% on-load tap-changer, YNd11 vector group, and optimized losses (no-load 0.34%) for continuous and stable power quality.

Product Overview

 

This series is an intelligent voltage-regulating two-winding main power transformer designed for 110kV grid users requiring strict voltage stability and power quality.

 

By integrating proven transformer technology with online on-load tap-changing (OLTC) functionality, it provides an ideal solution for dynamic voltage optimization, ensuring a continuous and high-quality power supply to critical loads.

 

110kV-transformer-internal-structurejpg

 

 

Technical Specifications

 

Rated capacity
(kVA)

Rated voltage and tapping range

Vector group

No Load Current
(%)

Short-circuit impedance
(%)

No load Losses
(kW)

On load Losses
(kW)

HV

Tapping range

LV

6300

110

±4×1.25
±6×1.25
±8×1.25

6.3
6.6
10.5
21

YNd11

0.51

10.5

4.4

32

8000

0.51

5.3

38

10000

0.47

6.2

45

12500

0.47

7.4

53

16000

0.44

8.9

66

20000

0.44

10.6

79

25000

0.41

12.5

94

31500

0.41

14.9

111

40000

0.37

10.5~18

17.8

140

50000

0.37

21

175

63000

0.34

25

209

 

 

110kV-transformer-voltage-regulation-diagramjpg

 

 

Core Advantages 

 

  • Dynamic Voltage Regulation (OLTC): Standard equipped with ±4×1.25%, ±6×1.25%, or ±8×1.25% tap ranges. Enables real-time voltage adjustment without power interruption. Prevents production downtime caused by grid fluctuations.
  • Flexible System Integration: HV rated at 110kV. LV side provides multiple distribution and industrial voltages (6.3kV, 6.6kV, 10.5kV, 21kV), perfectly matching various end-user connection scenarios.
  • Optimized Reliability & Efficiency: Standard YNd11 vector group simplifies relay protection. Short-circuit impedance is optimized for system stability, while no-load current is kept low (min 0.34%) to balance regulation precision with energy savings.
  • Wide Capacity Coverage: Ranging from 6.3 MVA to 63 MVA. Suitable for small-to-medium regional substations, industrial step-down substations, renewable energy grid connections, and user substations with strict power quality requirements.

110kV-transformer-OLTC-detailjpg

 

 

Typical Applications

 

  • 110kV substations in urban areas and industrial parks with strict requirements for voltage qualification rates.
  • Dedicated substations for critical power users such as data centers, high-end manufacturing, and public infrastructure.
  • Step-up substations for renewable energy projects (wind/PV), especially suitable for grid connection points with significant voltage fluctuations.
  • Regional grid interconnection substations serving voltage support and regulation functions.

Hot Tags: 110kv oil-immersed 3-phase 2-winding oltc power transformer, China 110kv oil-immersed 3-phase 2-winding oltc power transformer manufacturers, suppliers, factory, 110kv power transformer, 110kV Oil Immersed 3 Phase 3 Winding OLTC Power Transformer, power transformer, 110kV Oil Immersed 3 Phase 2 Winding OLTC Power Transformer, pad mounted transformer, 110kV Oil Immersed 3 Phase 2 Winding NLTC Power Transformer