10KV Dry Type Transformer

Your Leading 10KV Dry Type Transformer Supplier

 

Trust In Grid Co., Ltd. is a professional transformer manufacturer, specializing in the design and production of power transformer, high-voltage switchgear, power distribution equipment, energy storage systems (ESS), magnetic wire, bushing and machining parts. Our power transformers are available in 500KV, 330KV, 220KV, and 110KV models, and are widely used in power utilities, renewable energy systems (solar and wind), industrial facilities, data centers, transportation infrastructure, and OEM applications.

 

 
 
Why Choose Us?

 

Production Capacity

With 6 factories covering 240,000 m², over 2,000 employees, and 200+ engineers, we support large-scale projects and long-term global supply with more than 30 years of export experience.

Advanced Equipment

We operate a complete set of in-house production equipment, including cutting, winding, CNC machining, vacuum drying, and testing systems, with over 450 machines ensuring stable quality and efficient output.

Quality Control

All products are manufactured and tested in compliance with IEC, IEEE, ANSI, CSA, UL/cUL, CE, and ISO 9001:2015 standards, ensuring reliable performance and smooth international approval.

OEM & ODM Capability

Our engineering team provides OEM/ODM support, including customized design and technical optimization, delivering tailored solutions for utility, industrial, and renewable energy projects.

 

Specifications of 10KV Dry Type Transformer

 

Parameter

Specification

Product Type

10kV Dry Type Transformer

Rated Voltage (HV)

6kV / 6.6kV / 10kV / 11kV

Rated Voltage (LV)

0.4kV / 0.415kV / 0.48kV

Rated Capacity

30 kVA – 5000 kVA

Phase

Three-phase

Frequency

50 Hz / 60 Hz

Cooling Method

AN (Air Natural) / AF (Air Forced)

Insulation Class

Class F / Class H

Winding Material

Copper / Aluminum

Vector Group

Dyn11 / Yyn0

Tap Range

±2×2.5% or ±5%

Impedance Voltage

4% – 6%

Temperature Rise

≤100K

Partial Discharge

≤10 pC

Protection Class

IP00 / IP20 / IP23 / IP54

Installation Type

Indoor / Outdoor

Standards

IEC 60076 / IEC 60076-11 / IEEE / ANSI / GB

Altitude

≤1000 m

Ambient Temperature

≤40°C

 

10kV Dry Type NLTC Distribution Transformer

 

Advantages of 10KV Dry Type Transformer

Fire Safety and Environmental Protection
One of the main advantages of dry type transformers is their non-flammable construction. Since they contain no oil, there is no risk of explosion or contamination, aligning perfectly with the principles of eco-friendly and environmentally friendly engineering design.

 

Reduced Downtime and Maintenance
Dry-type transformers require minimal maintenance, as there are no oil samples to test or leaks to repair. Their reduced downtime leads to higher operational reliability and cost efficiency, especially in data centers and critical infrastructure, where uninterrupted power is crucial.

 

Energy Efficiency and Smart Monitoring
With the integration of smart sensors and IoT-based control systems, modern dry-type transformers allow real-time monitoring of temperature, load, and insulation health. These features improve energy efficiency, extend operational life, and support smart grid applications.

 

Competitive advantage

The company conducted a competitive advantage analysis to identify its strengths and weaknesses compared to its rivals.

Magnetic Core

Made of high-quality, low-loss silicon steel laminations, the core provides a path for the magnetic flux.

01

Windings (Primary & Secondary)

Made from copper or aluminum conductors, these are insulated with high-temperature materials (e.g., Nomex) and are responsible for voltage transformation.

02

Insulation System

The heart of a dry type transformer's durability. It's a combination of solid dielectric materials and air, rated for high temperatures (e.g., Class F or H).

03

Enclosure

A protective steel housing that shields the internal components from dust, moisture, and accidental contact. Its ventilation is crucial for cooling. The degree of protection is defined by an IP rating.

04

Taps

Allow for small adjustments to the turns ratio to compensate for variations in the supply voltage.

05

 

 

Application Industries of 10KV Dry Type Transformer

Commercial Buildings and Public Facilities
Such as hospitals, schools, shopping centers, and office buildings, where safety and environmental requirements are high.

 

Industrial Manufacturing and Mining
Adapt well to harsh environments with dust and humidity.

 

Data Centers and IT Facilities
Require quiet and efficient power supply; dry-type transformers are quiet and provide reliable power conversion.

 

Transportation Facilities
Subway stations, airports, and other high-traffic areas require safe and easy-to-maintain equipment.

 

Renewable Energy
Wind farms, solar power plants; dry-type transformers align with eco-friendly initiatives.

2. 10kV Dry Type NLTC Distribution Transformer

 

Customization Options

Material: Customizable

Structure: Customizable

MOQ: Customizable

 

Manufacturing Process

Core Lamination Process
The transformer core is manufactured using high-grade CRGO silicon steel to minimize core loss and improve efficiency.

 

Winding Process (Copper / Aluminum)
Windings are produced using high-conductivity copper or aluminum, depending on project requirements.

Vacuum Drying & Oil Filling

This process ensures optimal insulation performance and long-term reliability.

Testing & Quality Control

Each transformer undergoes strict testing procedures in accordance with international standards.

Final Assembly & Packaging

Final assembly ensures mechanical integrity and readiness for transportation and installation.

 

Test Methods for 10KV Dry Type Transformer

 

 

Transformer Turns Ratio Test
You do not need to do a Transformer Turns Ratio (TTR) Test unless you think the system has electrical problems. For instance, if you notice signs of discoloration during your inspection, electrical issues could be at fault, and you would need to do a TTR. For accuracy of this test and safety to your personnel, do not do a TTR test yourself. Instead, contact a professional who has access to the latest testing equipment for this service. An expert will have the tools and protective gear needed to run this test correctly and safely.

 

Dielectric Absorption Test
For a dielectric absorption test, conduct it for 10 minutes from windings to windings as well as the winding to the ground. This test uses measurements at 10 minutes and one minute and divides them in a ratio, the Polarization Index (PI) ratio. To be acceptable, the PI should be greater than 2.0.

 

Payment Terms

T.T with 30% downpayment, 70%before shipment.

Paypal or West Union also accept.

 

Our Service Highlights

 

 

Pre-Sales Consultation & Design Support
Early technical engagement to define requirements and deliver optimized solutions.

 

During Sales & Project Execution
Transparent project management with controlled production, quality tracking, and on-time delivery.

 

Warranty Advantage
Minimum 2-year warranty on all products, ensuring reliable and risk-free operation.

 

After-Sales Support
24/7 technical support with fast response, spare parts availability, and training services.

 

Long-Term Partnership
Lifelong technical support and upgrade guidance for sustained performance.

 

Packaging & Shipping

 

Packaging details:
Shockproof foam/moisture-proof film, professional export cartons/wooden crates/pallets.
Final assembly ensures mechanical integrity and readiness for transportation and installation. 

 

productcate-808-351

 

Certificates

 

 

productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1

 

FAQ

 

Q: Where is a 10kV dry type transformer typically installed?

A: It is mainly used in indoor substations, commercial buildings, industrial plants, and utility distribution networks.

Q: What makes 10kV a common distribution voltage level?

A: 10kV is widely used as a standard medium-voltage level for stepping down power from transmission to end-user distribution.

Q: Can this transformer be used in high humidity areas?

A: Yes, cast resin insulation provides moisture resistance, making it suitable for humid or coastal environments when properly enclosed.

Q: What is the main difference between dry type and oil-immersed transformers?

A: Dry type units use air cooling and solid insulation, while oil-immersed types rely on insulating oil for cooling and insulation.

Q: Can the transformer handle short-time overloads?

A: Yes, depending on design and cooling mode (especially AF systems), short-term overload capacity is available within defined limits.

Q: What cooling systems are available?

A: Standard operation uses natural air cooling (AN). Forced air cooling (AF) can be added for higher load conditions.

Q: Is it suitable for indoor substations with limited space?

A: Yes, compact structure and no oil system make it suitable for space-constrained indoor installations.

Q: What testing is done before delivery?

A: Routine tests typically include insulation resistance, ratio test, voltage withstand, and temperature rise verification.

We're well-known as one of the leading 10kv dry type transformer manufacturers and suppliers in China, also support customized service. Please feel free to buy high quality 10kv dry type transformer made in China here from our factory. Contact us for more details.

10kv dry type transformer, 10kV Dry Type NLTC Distribution Transformer, 10kV Dry Type NLTC Transformer for New Energy