Power Transformer

Trust in Grid (TIG) Main Transformers / Large Power Transformers

Grid-Level Reliability · EHV Large Capacity · Preferred Choice for Global Energy Infrastructure

 

Product Portfolio

 

Category

Specification Range

Application Scenarios

Power Transformer

10 MVA - 480 MVA

Power plant step-up, substation main transformer, grid backbone nodes

EHV Transformer

66kV - 500kV

Cross-regional power transmission, national grid backbone networks

 

Core Competitive Advantages

 

2

🔋 Large Capacity · High Energy Efficiency

Parameter

Trust in Grid Standard

Industry Advantage

Maximum Capacity

480 MVA single unit, up to 1000 MVA+ in parallel

Meets demands of large power plants and UHV stations

Efficiency Class

Compliant with IEC 60076-1 Ed.3.0 Tier 1 efficiency

40% reduction in no-load loss, 15% optimization in load loss

Short-circuit Impedance

Precisely designed (8%-20% adjustable), short-circuit withstand capability ≥25x rated current

Automatic protection during grid faults, zero damage record

Overload Capacity

150% rated load for 2 hours continuously

Handles peak power demand, no standby unit required

 

⚡ EHV · Fully Insulated Technology

- Full Voltage Range Coverage: 66kV / 110kV / 132kV / 220kV / 330kV / 400kV / 500kV
- Insulation System: Full vacuum oil filling + crepe paper shielding, PD <50pC (far below IEC standard of 100pC)
- Cooling System: ONAN/ONAF/OFAF/ODAF multi-mode intelligent switching, adaptable to tropical/frigid/desert environments
TIG Main Transformer Market Opportunity 2024-2032 Global Outlook Shell-Type Segment and US Strategy

 

🌍 Global Grid Certifications

Certification

Target Market

IEC 60076 / IEC 60137

Global (Europe, Africa, Southeast Asia, Middle East)

IEEE C57.12.00 / C57.12.90

North America, South America, Philippines

GOST

Russia, Central Asian countries

 

Technical Parameters (Typical Models)

 

TIG Main Transformer Market Opportunity 2024-2032 Global Outlook Shell-Type Segment and US Strategy

110kV Main Transformer

Parameter

Specification

Rated Power

31.5 MVA / 50 MVA / 63 MVA / 100 MVA

Voltage Combination

110±8×1.25%/38.5±2×2.5%/10.5kV

Vector Group

YNyn0d11

No-load Loss

≤25 kW (@50MVA)

Load Loss

≤140 kW (@50MVA)

Impedance Voltage

10.5% / 17.5% / 6.5% (HV-MV/HV-LV/MV-LV)

Cooling Method

ONAN/ONAF

 

220kV EHV Main Transformer

Parameter

Specification

Rated Power

120 MVA / 180 MVA / 240 MVA

Voltage Combination

220±8×1.25%/121/10.5kV or 220/115/37kV

Insulation Level

LI/AC 950/395 kV (HV side)

Cooling Method

ONAF/OFAF

Special Design

OLTC, online DGA, intelligent bushings

 

330kV EHV Main Transformer ⭐

TIG Oil-Immersed Power Transformer Internal Structure Diagram1

 

Parameter

Specification

Rated Power

180 MVA / 240 MVA / 360 MVA / 450 MVA

Voltage Combination

330±8×1.25%/121/10.5kV or 330/220/35kV or 330/110/35kV (three-winding)

Vector Group

YNa0d11 or YNyn0d11

Insulation Level

LI/AC 1175/510 kV (HV side) / LI/AC 550/230 kV (MV side)

No-load Loss

≤85 kW (@240MVA) / ≤120 kW (@360MVA)

Load Loss

≤480 kW (@240MVA) / ≤680 kW (@360MVA)

Impedance Voltage

14%-16% (HV-MV) / 24%-26% (HV-LV) / 8%-10% (MV-LV)

Cooling Method

OFAF / ODAF

Voltage Regulation

On-Load Tap Changer (MR or ABB brand, 17 or 21 steps)

Special Design

Online DGA, Fiber Optic Winding Temperature Sensing, Intelligent Bushing Monitoring, Digital Twin System

Transport Mode

Three-phase integral (≤240MVA) / Single-phase modular (≥360MVA, site assembly)

 

Max. Capacity & Voltage in Mass Production for Export: 250MVA / 345kV (Fully Insulated EHV Transformer). This model was manufactured and shipped to the USA in 2025.

 

500kV UHV Main Transformer (Customized)
- Capacity: 300 MVA - 1000 MVA
- Three-phase integral or single-phase modular (for transport convenience)
- Cooling: ODAF
- Digital Twin Remote Monitoring System

 

Key Technologies & Quality Control


TIG Power Transformer Manufacturing Precision Engineering from Core to Tank

 

Manufacturing Capabilities

Process

Trust in Grid Advantage

Core

Japanese imported ZDKH high-permeability grain-oriented silicon steel, Step-lap joints, 30% reduction in no-load loss

Windings

Continuously transposed conductors (CTC), short-circuit withstand capability enhanced to 50kA/2s

Insulation

German imported pressboard, dryness ≤0.5%, dielectric strength ≥40kV/mm

Tank

Integral welding + helium leak detection, ensuring 30 years of no leakage

Final Assembly

Fully enclosed dust-free workshop, vacuum ≤0.1mbar, maintained for 24 hours

 

Routine Tests (100% Inspected)

- ✅ Winding DC resistance measurement
- ✅ Voltage ratio and vector group verification
- ✅ No-load loss and current measurement
- ✅ Load loss and impedance voltage measurement
- ✅ Power-frequency withstand voltage test (AC)

- ✅ Induced voltage withstand test (IVPD)
- ✅ Lightning impulse test (LI)
- ✅ Partial discharge measurement
- ✅ Temperature rise test (Type test)
- ✅ Dissolved Gas Analysis (DGA)

 

productcate-400-468 - ✅ Winding DC resistance measurement
productcate-400-271 - ✅ Voltage ratio and vector group verification
productcate-400-300 - ✅ No-load loss and current measurement
productcate-400-276 - ✅ Load loss and impedance voltage measurement
productcate-400-300 - ✅ Power-frequency withstand voltage test (AC)
productcate-400-267 - ✅ Induced voltage withstand test (IVPD)
productcate-400-300 - ✅ Lightning impulse test (LI)
productcate-400-257 - ✅ Partial discharge measurement
productcate-400-274 - ✅ Temperature rise test (Type test)
productcate-400-249 - ✅ Dissolved Gas Analysis (DGA)

 

Foreign Trade Specialized Services (Large Project Customization)

 

TIG Power Transformer Project Logistics Installation Loading Haulage and Site Commissioning

🚢 Logistics and Delivery

Item

Service Content

Transport Solution

Special heavy-haul vehicles + Ro-Ro vessels, supports CIF/CIP/DAP/DAP terms

Site Assembly

Ultra-large transformers can be shipped as split units (core + tank, coolers, bushings), on-site guidance by engineers

Installation & Commissioning

Dispatch senior engineer teams (English/French/Arabic/Russian), provide installation supervision, commissioning, and energization services

Training Services

On-site training for client O&M teams, issuance of operation and maintenance certificates

 

💰 Commercial Support

Item

Policy

Payment Terms

Accepts L/C at sight for large projects, negotiable milestone-based payments

Financing Support

Coordination with Sinosure, Export-Import Bank of China preferential loans

 

Global Success Stories


TIG Power Transformers Trusted in 73 Countries Worldwide

 

Country/Region

Project

Specification

Year

Ethiopia

Addis Ababa Substation Expansion

3×63MVA 132/33kV

2023

South Africa

Eskom Grid Upgrade

5×100MVA 400/132kV

2022

Saudi Arabia

SEC Southern Province Transmission Project

8×50MVA 132/13.8kV

2023

Egypt

New Administrative Capital Power Supply

4×180MVA 220/66kV

2024

Indonesia

PLN National Grid

6×31.5MVA 150/20kV

2023

Chile

Mining Company Captive Power Plant

2×75MVA 220/23kV

2022

 

FAQ (For Large Capacity Projects)

 

Q: How are ultra-large capacity transformers (>200MVA) transported?

A: Large main transformers adopt a detachable transport scheme. The active part and main tank are transported as an integral unit, while radiators, conservator, bushings and other accessories are dismantled and transported separately, then reassembled on site.

Component

Handling Method

Active Part + Main Tank

Integral transport, kept under positive pressure with nitrogen or dry air

Radiators/Coolers

Dismantled and transported separately, reassembled and oil-filled on site

Conservator and Accessories

Dismantled and transported separately, including gas relay, dehydrating breather

Bushings

Dismantled and transported separately; 330kV and above capacitive bushings require vertical storage/transport

On-Load Tap Changer (OLTC)

Transported with active part or dismantled separately

Intelligent Components

Secondary equipment like online DGA, FOTS, PD Monitoring secured with anti-vibration packaging

Key On-Site Procedures: Vacuum oil filling → Hot oil circulation → Commissioning tests.

Q: Do you participate in EPC turnkey projects?

A: Yes. We can act as a transformer supplier in substation EPC projects or jointly bid with local partners, providing full services from design, supply, installation to commissioning.

Q: How is after-sales service guaranteed in remote areas like Africa or South America?

A: We have regional service centers in Nairobi (Kenya), Johannesburg (South Africa), Dubai (UAE), and Sao Paulo (Brazil), stocking critical spare parts. We commit to a 48-hour response and on-site arrival within 7 days.

Q: Can you assist with grid company type tests or acceptance tests?

A: Absolutely. We are familiar with grid access procedures in various countries. We provide complete type test reports and can cooperate with local grid companies (e.g., Ethiopia EEU, South Africa Eskom) to conduct on-site acceptance tests.

Q: What tender documents are needed for project bidding?

A: We can provide a full set of tender support documents, including: ISO certifications, type test reports, bank credit certificates, reference lists, factory inspection invitations, and third-party (BV/SGS) inspection reports.

 

Inquire Now
Dedicated Channel for Large Projects
📧 Project Email: asia@trustingird.com
📞 Global Hotline: +86-157-1629-5780 (Bilingual Chinese/English)
🌐 Website: www.trustingird.com
Please provide the following information for a precise quotation
- Rated Power (MVA)
- Voltage Level (kV)
- Operating Environment (Altitude/Temperature/Humidity)
- Preferred Cooling Method
- Target Market / Required Certifications
- Project Timeline
Trust in Grid Transformer — Empowering Global Grid Infrastructure
30 Years Specializing in Large Power Transformers · Serving Energy Construction in 70+ Countries · Total Installed Capacity Exceeds 50,000 MVA

We're well-known as one of the leading power transformer manufacturers and suppliers in China, also support customized service. Please feel free to buy high quality power transformer made in China here from our factory. Contact us for more details.