Your Leading Medium Voltage (MV) Switchgear Supplier

 

Trust In Grid Co., Ltd. is a professional transformer manufacturer, specializing in the design and production of power transformer, high-voltage switchgear, power distribution equipment, energy storage systems (ESS), magnetic wire, bushing and machining parts. Our power transformers are available in 500KV, 330KV, 220KV, and 110KV models, and are widely used in power utilities, renewable energy systems (solar and wind), industrial facilities, data centers, transportation infrastructure, and OEM applications.

 

 
 
Why Choose Us?

 

Production Capacity

With 6 factories covering 240,000 m², over 2,000 employees, and 200+ engineers, we support large-scale projects and long-term global supply with more than 30 years of export experience.

Advanced Equipment

We operate a complete set of in-house production equipment, including cutting, winding, CNC machining, vacuum drying, and testing systems, with over 450 machines ensuring stable quality and efficient output.

Quality Control

All products are manufactured and tested in compliance with IEC, IEEE, ANSI, CSA, UL/cUL, CE, and ISO 9001:2015 standards, ensuring reliable performance and smooth international approval.

OEM & ODM Capability

Our engineering team provides OEM/ODM support, including customized design and technical optimization, delivering tailored solutions for utility, industrial, and renewable energy projects.

 

Technical Specifications of Medium Voltage (MV) Switchgear

 

Parameter Category

Technical Specification

Rated Voltage

7.2kV, 12kV, 17.5kV, 24kV, AC 50/60Hz

Rated Current (Main Busbar / Circuit Breaker)

Main Busbar: Up to 3150A; Breaker Unit: 630A, 1250A, 2000A, 2500A, 3150A

Rated Short-Circuit Breaking Current (Isc)

25kA, 31.5kA, 40kA, compliant with IEC 62271-100

Rated Short-Time Withstand Current (Icw)

Matches Isc rating, typical 25kA / 4s, 31.5kA / 4s

Rated Peak Withstand Current (Ipk)

63kA, 80kA, 100kA (2.5 x Icw), compliant with IEC 62271-1

Power-Frequency Withstand Voltage (1 min)

42kV (for 12kV class), compliant with IEC 62271-1

Lightning Impulse Withstand Voltage

75kV (for 12kV class), compliant with IEC 62271-1

Degree of Protection (IP Code)

Standard IP4X (between compartments), IP3X (enclosure)

Applicable Standards

IEC 62271-200 (AC metal-enclosed switchgear and controlgear), IEC 62271-1, IEC 62271-100

 

The Main Functions of a Medium Voltage (MV) Switchgear
 

Fault detection

Internal sensors and protective relays constantly monitor current and voltage for sudden surges caused by short circuits or overloads.

Rapid interruption

Upon detection, the relay commands a circuit breaker to open the circuit in milliseconds, isolating the damaged section before the massive energy can cause fire or equipment destruction.

Load switching

Engineers can close or open specific circuits to connect or disconnect equipment, allowing power to be rerouted during equipment upgrades or maintenance.

Monitoring and automation

Modern MV switchgear is often digitally native, allowing for remote monitoring and control, which improves efficiency and grid resilience (smart grid functionality).

Visible separation

Using a disconnect switch, also known as an isolator, an air gap is created to separate equipment from live power, ensuring the circuit is fully de-energised for work.

Switching devices

The separation can also be achieved through devices such as a fuse switch disconnector, an earthing switch, or a circuit breaker.

 

KYN28-12KV Metal-Clad Withdrawable Switchgear

 

Components of a Medium Voltage (MV) Switchgear

MV switchgear consists of several integrated components that work together to ensure safe electrical operation.

 

Circuit Breaker
The circuit breaker is one of the most important components. It automatically interrupts electrical current during faults such as short circuits or overloads.

 

Disconnect Switch
A disconnect switch isolates electrical circuits for maintenance and safety purposes.

 

Busbars
Busbars are conductive bars that distribute electrical power within the switchgear assembly.

 

Protection Relays
Protection relays monitor electrical parameters and trigger circuit breakers when abnormal conditions occur.

 

Current and Voltage Transformers
These transformers measure electrical current and voltage levels to support monitoring and protection systems.

 

Customization Options

 

Structure

Customizable based on project requirements

Material

Customizable (steel, stainless steel, or others)

Logo

Customizable

MOQ

Flexible

 

 

Application of Medium Voltage (MV) Switchgear

Power Distribution Networks
Utilities use MV switchgear to distribute electricity from substations to local distribution systems.

 

Industrial Plants
Factories rely on MV switchgear to control power supply to heavy machinery and production lines.

 

Renewable Energy Systems
Wind farms and solar power plants use MV switchgear to integrate energy generation into the grid.

 

Commercial Infrastructure
Airports, hospitals, shopping centers, and large office buildings use MV switchgear for reliable power management.

 

Transportation Systems
Railways and metro systems use MV switchgear for traction power distribution.

KYN28-12KV Metal-Clad Withdrawable Switchgear

 

Comparison of MV Switchgear and LV Switchgear

 

Feature

Medium Voltage

Low Voltage

Voltage Range

1 – 36 kV

≤ 1 kV

Applications

Grids, factories

Homes, devices

Equipment

Switchgear, relays

Fuses, breakers

Risk & Handling

Requires PPE, training

General safety

 

 
Maintenance of of Medium Voltage (MV) Switchgear
 
01/

Routine Visual Inspection
Regularly check for dust accumulation, signs of corrosion, oil/gas leaks, loose fasteners, or discoloration (a sign of overheating).

02/

Cleaning & Lubrication
Keep contact surfaces clean and apply lubricants to moving parts as needed to reduce friction and wear. Always de-energize before servicing.

03/

Testing & Calibration
Periodically test protective relays, current transformers, and breakers. Ensure interrupting devices trip within safe time limits.

04/

Scheduled Shutdowns
Plan annual maintenance windows to perform deeper inspections, insulation resistance testing, and component replacements without interrupting critical operations.

 

Ordering Process

 

Send Us Inquiry → Receive Our Quotation → Negotiate Details → Confirm the Sample → Sign Contract/Deposit → Mass Production →Cargo Ready → Balance/Delivery → Further Cooperation 

 

Payment Terms
 

T.T with 30% downpayment, 70%before shipment.

Paypal or West Union also accept.

 

 

Customization Options
 

Material: Cu / Al

Cooling system: Customizable

Structure: Customizable

MOQ: Customizable

 

Our Service Highlights

 

 

Pre-Sales Consultation & Design Support
Early technical engagement to define requirements and deliver optimized solutions.

 

During Sales & Project Execution
Transparent project management with controlled production, quality tracking, and on-time delivery.

 

Warranty Advantage
Minimum 2-year warranty on all products, ensuring reliable and risk-free operation.

 

After-Sales Support
24/7 technical support with fast response, spare parts availability, and training services.

 

Long-Term Partnership
Lifelong technical support and upgrade guidance for sustained performance.

 

Packaging & Shipping

 

Packaging details:
Shockproof foam/moisture-proof film, professional export cartons/wooden crates/pallets.
Final assembly ensures mechanical integrity and readiness for transportation and installation. 

 

productcate-808-351

 

Certificates

 

 

productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1

 

FAQ

 

Q: What types of insulation are available for MV switchgear?

A: Common options include air-insulated and gas-insulated (SF6) designs, depending on space and safety requirements.

Q: Is MV switchgear suitable for outdoor installation?

A: Yes, outdoor configurations are available with weather-resistant enclosures for harsh environments.

Q: Can MV switchgear be integrated into existing systems?

A: Yes, it can be designed to match existing layouts, electrical schemes, and connection standards.

Q: What switching devices are typically used inside MV switchgear?

A: Vacuum circuit breakers are commonly used due to their reliability and low maintenance needs.

Q: How is operator safety ensured in MV switchgear?

A: Safety features include interlocking systems, arc fault containment, and clear operational separation.

Q: What is the typical maintenance requirement?

A: Routine inspection is recommended, but modern MV switchgear is designed for low maintenance operation.

Q: Can you support different component brands?

A: Yes, components can be selected based on customer preference or project specifications.

Q: How do you ensure product quality before delivery?

A: Each unit is assembled and tested according to standard procedures to verify performance and safety.

We're well-known as one of the leading medium voltage (mv) switchgear manufacturers and suppliers in China, also support customized service. Please feel free to buy high quality medium voltage (mv) switchgear made in China here from our factory. Contact us for more details.