FZW32-12 40.5kV Series Outdoor High Voltage Vacuum Isolating Load Break Switch
video
FZW32-12 40.5kV Series Outdoor High Voltage Vacuum Isolating Load Break Switch

FZW32-12 40.5kV Series Outdoor High Voltage Vacuum Isolating Load Break Switch

Our FZW32 series outdoor vacuum isolating load break switches combine vacuum arc extinction with a visible isolating gap for safe, maintenance-free operation.

• Rated up to 40.5kV, 1250A; short-circuit making current up to 63kA.

• Mechanical endurance of 10,000 operations; stainless steel housing for outdoor reliability.

• Visible isolating gap ensures clear open position for enhanced safety.

• Fast delivery, reliable quality, and extensive project experience.

Product Overview

 

The FZW32-12/40.5kV Outdoor High-voltage Disconnecting Vacuum Load Break Switch (hereinafter referred to as the Load Switch) is a new generation of high-voltage electrical apparatus manufactured by our company. Having undergone rigorous type tests and long-term trial operation assessments, all technical performance indicators fully comply with the GB3804 and IEC standards. It is suitable for use in power supply networks with a rated voltage of 40.5kV, a rated current of 1250A, and three-phase AC 50Hz.

 

FZW32-12 40.5kV Series Outdoor High Voltage Vacuum Isolating Load Break Switch

 

S.Q.

Item

Unit

Parameter

1

Rated Voltage

kV

12

40.5

2

Rated Frequency

Hz

50

50

3

Rated Current

A

630

1250

4

Rated Active Load Breaking Current

A

630

1250

5

Rated Closed-loop Breaking Current

A

630

1250

6

5% Rated Active Load Breaking Current

A

31.5

62.5

7

Rated Cable Charging Breaking Current

A

10

25

8

Power Frequency Withstand Voltage (1 min): Vacuum Interrupter Gap, Between Phases, Phase-to-earth / Isolating Distance

kV

42/48

68/95/110

9

Lightning Impulse Withstand Voltage: Between Phases, Phase-to-earth / Isolating Distance

kV

75/85

185/215

10

Rated Short-time Withstand Current (Thermal)

kA

20

25

11

Rated Short-circuit Duration

S

4

4

12

Rated Peak Withstand Current (Dynamic)

kA

50

63

13

Rated Short-circuit Making Current

kA

50

63

14

Mechanical Endurance

Times

10000

10000

15

Allowable Contact Erosion Thickness of Vacuum Interrupter

mm

0.5

0.6

16

Manual Operating Torque

nm

≤200

≤300

17

Earthing Blade Mechanical Endurance

Times

2000

2000

18

Earthing Blade Dynamic Withstand

kA

40

40

 

Product Description

 

1. Employs vacuum arc extinction, with no explosion hazard and no need for maintenance.

2. The disconnecting blade is interlocked with the three-phase vacuum interrupters, providing a clear isolating gap in the open position.

3. All components of the housing are made of stainless steel. The base frame is constructed from stainless steel or hot-dip galvanized carbon steel coated with UV-resistant paint, ensuring reliable operation in outdoor environments.

4. The mounting method is primarily double-pole type with motor operation. Electric or remote control operation is also available.

5. High breaking capacity, safe and reliable, long electrical life, suitable for frequent operation.

6. Widely applicable for distribution line upgrades in rural, urban, and railway networks.

 

Operating Principle

 

- The load switch consists of two main components: the disconnecting blade and the vacuum interrupters. The disconnecting blade provides insulation during closing and opening operations, while the vacuum interrupters are responsible for arc extinction.

- The disconnecting blade is closed by a spring toggle mechanism. The toggle spring supplies the energy required for closing the blade and ensures the vacuum interrupters quench the arc during opening without being affected by human factors. During the opening process of the disconnecting blade, a quick-acting mechanism provides the opening speed for the interrupters. The three-phase interlocked operation of the disconnecting blade ensures the periodic opening of the interrupters.

 

Model Designation Breakdown

 

  • F: Load Switch
  • Z: Vacuum Interruption
  • W: Outdoor
  • 32: Design Sequence
  • 12: Rated Voltage (kV)
  • 40.5: Highest Voltage for Equipment (kV)
  • kV: Voltage Unit

Hot Tags: fzw32-12 40.5kv series outdoor high voltage vacuum isolating load break switch, China fzw32-12 40.5kv series outdoor high voltage vacuum isolating load break switch manufacturers, suppliers, factory, FKRN12A 12 Series 12kV Indoor Gas Insulated Load Break Switch, FLW36 12 24 40 5kV Series Outdoor High Voltage SF6 Load Break Switch, FZN25 12 Series 12kV Indoor Vacuum Load Break Switch, FZRN25 12D Series Vacuum Isolating Load Break Switch Fuse Combination Unit, FZW32 12 40 5kV Series Outdoor High Voltage Vacuum Isolating Load Break Switch