FLW36-12 24 40.5kV Series Outdoor High Voltage SF6 Load Break Switch
video
FLW36-12 24 40.5kV Series Outdoor High Voltage SF6 Load Break Switch

FLW36-12 24 40.5kV Series Outdoor High Voltage SF6 Load Break Switch

Our FLW36 series pole-mounted outdoor SF6 load break switches provide reliable load switching and automatic fault isolation for 12–40.5kV distribution networks with integrated remote monitoring capabilities.

• Rated up to 40.5kV, 630A; spring-energy mechanism ensures operation under 100ms.

• 304L stainless steel construction with 30-year service life; color-coded position indicator visible from ground.

• Electronic controller enables local, motor, and remote operation with FTU interface; wired/wireless modem options for remote monitoring.

• Factory-filled SF6 gas; zero gauge pressure withstand of 30kV.

• Adaptable to altitudes up to 3000m, temperatures from -40°C to +50°C, and pollution Class IV.

• Fast delivery, reliable quality, responsive service, and extensive project experience backed by our company.

Product Overview

 

The FLW36-12/24/40.5 type pole-mounted outdoor load break switch is suitable for making and breaking load currents and overload currents in distribution networks with rated voltages of 12/24/40.5kV, a rated current of 630A, and 50/60Hz. It can automatically isolate faulty sections of the distribution line. The switch is equipped with a state-of-the-art electronic controller, allowing for manual operation, motor operation, and remote operation. The electronic controller is housed in a stainless steel enclosure, suitable for use in various climatic conditions. Furthermore, wired and wireless modems can be installed within the enclosure to enable remote monitoring and control.

 

Technical Specifications

 

S.Q.

Item

Unit

Parameter

1

Rated Voltage

kV

12

24

40.5

2

Rated Frequency

Hz

50/60

50/60

50/60

3

Rated Insulation Level (at filled SF6 gas pressure 0.07 MPa / 20°C)

Lightning Impulse Withstand Voltage

Between phases, Phase-to-earth

kV

75

125

185

Interrupter unit gap

85

145

215

Power Frequency Withstand Voltage (1 min)

Between phases, Phase-to-earth

42

64

95

Interrupter unit gap

50

79

110

4

Insulation Level at Zero Gauge Pressure

Power Frequency Withstand Voltage (1 min)

kV

30

Power Frequency Withstand Voltage (1 min) Reverse Polarity

30

Highest Phase Voltage (5 min) Between Phases and Phase-to-earth

9

5

Rated Current

A

630

630

630

6

Rated Load Breaking Current (at 0.07 MPa / 20°C)

A

630

630

630

 

Simple pole-mounted installation is convenient and fast, reducing construction costs.

 

Product Features

 

1. SF6 gas is a non-toxic, non-flammable electrical insulating gas with excellent arc-quenching characteristics.

2. In addition to standard ceramic bushings, multiple options are available, including rubber insulators on environmentally friendly apparatus bushings.

3. The color-coded main contact position indicator (green-open, red-closed) is easily visible from the ground. This indicator is directly connected to the main contact drive shaft assembly, ensuring accurate display of the contact status.

4. A spring-energy storage operating mechanism ensures rapid closing and opening operations (less than 100 milliseconds).

5. Equipped with an electronic controller for local operation or master console operation via an FTU interface.

6. The switch is constructed from proven, robust, and corrosion-resistant materials (warship-grade 304L1 stainless steel plate), ensuring a long service life (30 years) and the capability to perform a series of operations, embodying ideal characteristics for pole-mounted equipment.

7. Each switch is factory-filled with SF6 gas, sealed, and tested in accordance with IEC 60265-1 (1988) and GB3804-1990 standards.

 

Model Designation Breakdown

 

F: Load Break Switch

L: SF6 (Sulfur Hexafluoride)

W: Outdoor

36: Design Sequence

12/24/40.5: Rated Voltage Series (kV)

Note: The "12/24/40.5" in the model designation indicates that this product series covers three voltage ratings: 12kV, 24kV, and 40.5kV.

 

Service Environmental Conditions

 

This SF6 gas load break switch is suitable for the following operating conditions:

1. Ambient air temperature: Upper limit +50℃, lower limit -40℃

2. Relative humidity: Up to 100%

3. Altitude not exceeding 3000m

4. Wind pressure not exceeding 700 Pa (equivalent to a wind speed of 34 m/s)

5. Seismic intensity: Degree 8

6. Installation site: Free from fire and explosion hazards, chemical corrosion, and frequent severe vibration

7. Pollution degree: Class III, Class IV

Hot Tags: flw36-12 24 40.5kv series outdoor high voltage sf6 load break switch, China flw36-12 24 40.5kv series outdoor high voltage sf6 load break switch manufacturers, suppliers, factory, electrical load break switches, FKRN12A 12 Series 12kV Indoor Gas Insulated Load Break Switch, FZW32 12 40 5kV Series Outdoor High Voltage Vacuum Isolating Load Break Switch, load break switch, FLW36 12 24 40 5kV Series Outdoor High Voltage SF6 Load Break Switch, transformer load break switch

Send Inquiry