VZF(R)-12 Series Indoor AC High Voltage Vacuum Load Break Switch
video
VZF(R)-12 Series Indoor AC High Voltage Vacuum Load Break Switch

VZF(R)-12 Series Indoor AC High Voltage Vacuum Load Break Switch

Our VZF(R)-12 indoor AC high voltage vacuum load switch is a high-performance solution for 12kV distribution networks, featuring a maintenance-free vacuum interrupter and optional fuse protection.

• Rated at 12kV, 630A (125A with fuse), with 50kA short-circuit making and 20kA short-time withstand current.

• Vacuum interruption technology ensures superior breaking capacity for transformers (1250kVA) and cables (16A charging current), with mechanical life of 10,000 operations.

• Low partial discharge level ≤5pC enhances insulation longevity; power-frequency withstand voltage 42kV, lightning impulse 75kV for reliable insulation performance.

• Compact design with flexible mounting dimensions (650/800/1000mm cabinet widths) for easy integration into air-insulated switchgear.

• Wide operating temperature range (-15°C to +40°C, storage at -30°C) and seismic withstand (Magnitude 8) for harsh environments.

• Fast delivery, reliable quality, responsive service, and extensive project experience backed by our company.

Product Overview

 

VZF(R)-12 Indoor AC High Voltage Vacuum Load Switch is a new generation of vacuum switchgear developed based on a unique design concept and in response to market demands. It is widely used in indoor armored air-insulated switchgear. It complies with the standards GB3804-2004 and GB16926-1997. Under normal operating conditions, as long as it operates within the technical parameters of the vacuum switch, it ensures safe and reliable operation in power grids of corresponding voltage levels.

 

Type Designation

 

VZF(R)-12 / T □ - □ - □ - □ - □ - □

- Vacuum load switch

- Fuse

- Rated voltage (kV)

- Operating mechanism: T represents spring-operated mechanism

- Rated current (A)

- Rated short-circuit breaking current (kA)

- Control voltage type

- Control voltage (V)

- Distance between poles (mm)

- Phase spacing (mm)

 

Operating Conditions

 

1. Ambient temperature: not exceeding +40°C, not lower than -15°C (storage and transport permitted at -30°C).

2. Altitude: not exceeding 1000m.

3. Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%; saturated vapor pressure daily average not exceeding 2.2×10⁻³ MPa, monthly average not exceeding 1.8×10⁻³ MPa.

4. Seismic intensity: not exceeding magnitude 8.

5. Locations free from fire, explosion hazards, severe pollution, chemical corrosion, and intense vibration.

Technical Specifications

 

No.

Parameter

Unit

Value 1

Value 2

1

Rated voltage

kV

12

12

2

Power-frequency withstand voltage (phase-to-phase and earth)

kV

42

42

3

Lightning impulse withstand voltage (phase-to-phase and earth)

kV

75

75

4

Rated current

A

630

125 (for fuse)

5

Rated short-circuit breaking withstand current

kA

50 (for fuse)

-

6

Rated short-time withstand current

kA

20

-

7

Rated peak withstand current

kA

50

-

8

Rated short-circuit making current

kA

50

-

9

Rated cable charging breaking current

A

16

-

10

Rated AC breaking current

A

3150

-

11

Breaking capacity for no-load transformer

kVA

1250

-

 

Outline and Mounting Dimensions

 

Cabinet Width (mm)

P (mm)

A (mm)

B (mm)

C (mm)

E (mm)

Weight (kg)

650

150

500

530

490

203

120

800

210

650

680

640

278

140

1000

275

850

880

840

378

160

Hot Tags: vzf(r)-12 series indoor ac high voltage vacuum load break switch, China vzf(r)-12 series indoor ac high voltage vacuum load break switch manufacturers, suppliers, factory, indoor vacuum circuit breaker, ZN85 40 5 Series Indoor High Voltage Vacuum Circuit Breaker, ZN63 VS1 24 Series Indoor AC High Voltage Vacuum Circuit Breaker, ZN63 VS1 12 Series Indoor High Voltage Vacuum Circuit Breaker, ZN63 VS1 12 Series Indoor Epoxy Cast Pole Vacuum Circuit Breaker, ZN28 12 Series Indoor High Voltage Vacuum Circuit Breaker