GW13-40.5 72.5 126 Outdoor Neutral Disconnector
video
GW13-40.5 72.5 126 Outdoor Neutral Disconnector

GW13-40.5 72.5 126 Outdoor Neutral Disconnector

Our GW13 series outdoor neutral disconnectors feature a 50° angle between post insulators with 25° base tilt, delivering reliable isolation for neutral point applications in 40.5–126kV systems.

• Rated voltage up to 126kV with current up to 2000A; short-time withstand up to 50kA/4s and peak withstand up to 125kA.

• Mechanical endurance of 10,000 operations; compatible with CS17G manual or CJ6 motor-operated mechanisms.

• Terminal load capacity of 1000N longitudinal and 750N transverse/vertical for robust field installation.

• Pollution-resistant option available with creepage distance up to 3906mm; adaptable to altitudes up to 2000m.

• Fast delivery, reliable quality, responsive service, and extensive project experience backed by our company.

Product Overview

 

The disconnector is composed of the support frame, base, post insulators, contacts, and terminal pads. The post insulators and conductive parts are mounted on the base, with an included angle of 50° between the two post insulators. The base is fixed on the support frame, which is tilted at 25°. The support frame is equipped with a shaft connected to the operating mechanism. It can be fitted with a CS17G manual operating mechanism or motor-operated mechanisms such as CJ6.

 

Technical Specifications

 

Designation

Unit

Parameter

Rated Voltage

kV

40.5,72.5,126

Rated Insulation Level

1-minute Power-frequency Withstand Voltage (r.m.s.)

to Earth

kV

95,160,230

across the isolating distance

kV

118,200,230+70

Rated Lightning Impulse Withstand Voltage (peak)

to Earth

kV

185,350,550

across the isolating distance

kV

215,410,550+100

Rated Frequency

Hz

50

Rated Current

A

630,1250,1600,2000

Rated Short-time Withstand Current

kA

20,31.5,40,50

Rated Peak Withstand Current

 

kA

50,80,100,125

Rated Short-circuit Duration (Main Switch / Earthing Switch)

 

S

4/2

Rated Terminal Mechanical Load

Longitudinal

N

1000

Transverse

N

750

Vertical

N

750

Creepage Distance

mm

1013,1256,1813,2284,3150,3906

Mechanical Endurance

 

times

10000

Motor-operated Mechanism

Model

 

CJ6B

Motor Supply Voltage

V

AC380,AC220,DC220,DC110

Control Circuit Voltage

V

AC380,AC220,DC220,DC110

Opening Time, Closing Time

S

 

Manual-operated Mechanism

Model

 

CS17,CS17D,CS170D,CS17-G-G₆

Solenoid Lock Supply Voltage

V

AC220,DC110,DC110

Total Weight

Without Earthing Switch

kg

300,350,400

With One Earthing Switch

kg

510,585,660

With Two Earthing Switches

kg

800,900,1000

 

Model and Its Designation

 

G W 13 - 40.5, 72.5, 126 (W)

G: General Purpose Disconnector

W: For Outdoor Installation

13: Design Serial Number

40.5, 72.5, 126: Rated Voltage (kV)

(W): Pollution Resistant Type (Optional)

 

 

Ordering Information

 

When placing an order, please specify the following:

Model and specification of the outdoor disconnector.

Model of the operating mechanism.

Name and quantity of required spare parts, special tools, and equipment (to be ordered separately).

Hot Tags: gw13-40.5 72.5 126 outdoor neutral disconnector, China gw13-40.5 72.5 126 outdoor neutral disconnector manufacturers, suppliers, factory, GN30 12 Indoor Rotary High Voltage Disconnector, disconnector isolator , GN27 GN2 40 5 Indoor High Voltage Disconnector, GN19 12 Indoor High Voltage Disconnector, GW5 40 5 72 5 126 Outdoor High Voltage AC Disconnector, GW4 72 5 126 Outdoor High Voltage AC Disconnector

Send Inquiry