LW16-40.5 Series SF6 Circuit Breaker
video
LW16-40.5 Series SF6 Circuit Breaker

LW16-40.5 Series SF6 Circuit Breaker

Our LW16-40.5 series outdoor SF6 circuit breakers are designed for control and protection in 35kV power systems, serving as an ideal oil-free replacement for SW2-35 minimum-oil and bulk-oil circuit breakers.

• Rated voltage of 40.5kV with rated current options at 1600A and 2000A; rated short-circuit breaking current up to 31.5kA with short-circuit making current up to 63kA.

• Equipped with built-in current transformers for measurement and protection; suitable for frequent operations, tie applications, and switching capacitor banks and reactor banks.

• Mechanical endurance of 3000 operations with rated short-circuit breaking operations of 21 times; cumulative breaking operations at rated current up to 2000 times.

• Capacitor bank breaking current up to 400A; rated out-of-phase breaking current of 6.3kA; operating duty of O-0.3s-CO-180s-CO.

• Designed for harsh environments with altitude up to 3000m, temperature from -25°C to +40°C, and pollution level Class IV with creepage distance >1255mm.

• When fitted with filtering bracket, can replace various models of bulk-oil circuit breakers for flexible retrofit applications.

• Fast delivery, reliable quality, responsive service, and extensive project experience backed by our company.

Product Overview

 

The LW16-40.5 side-mounted and center-mounted circuit breaker is designed for outdoor installation in three-phase AC 50Hz power systems, serving industrial plants, power plants, and substations for control and protection purposes. This product is suitable for frequent operations and can be used as a tie circuit breaker or for switching capacitor banks and reactor banks. Equipped with built-in current transformers for measurement and protection, it can directly replace the SW2-35 type minimum-oil circuit breaker. When fitted with a filtering bracket, it can also replace various models of bulk-oil circuit breakers. It serves as an ideal oil-free circuit breaker solution for 35kV power systems.

 

Technical Specifications

 

S.Q.

Item

Unit

Technical Parameter

1

Rated Voltage

kV

40.5

2

Rated Insulation Level

1-minute Power-frequency Withstand Voltage

kV

95

Lightning Impulse Withstand Voltage

185

3

Rated Frequency

HZ

50

4

Rated Current

A

1600,2000

5

Rated Short-circuit Breaking Current

KA

25 (auto-reclosing), 31.5 (single opening)

6

Rated Short-circuit Making Current

kA

63

7

Rated Short-time Withstand Current

kA

25

8

Rated Short-circuit Duration

S

4

9

Rated Peak Withstand Current

kA

63

10

Rated Operating Sequence

 

O-0.3s-CO-180s-CO

11

Rated Breaking Current of Single Capacitor Bank

A

400

12

Rated Out-of-phase Breaking Current

kA

6.3

13

Rated Phase-to-phase Breaking Current

kA

21.75

14

Mechanical Life Test

times

3000

15

Cumulative Breaking Operations at Rated Current

times

2000

16

Rated Short-circuit Breaking Operations

times

21

 

Operating Environmental Conditions

 

1. Altitude: Not exceeding 3000m;

2. Ambient Temperature: -25℃ to +40℃;

3. Wind Speed: Not exceeding 34m/s;

4. Pollution Level: Class IV; Creepage Distance of Porcelain Housing: >1255mm;

5. Locations free from flammable materials, explosion hazards, chemical corrosion, and severe vibration.

Note: For conditions beyond the above requirements, users may negotiate with the manufacturer.

Hot Tags: lw16-40.5 series sf6 circuit breaker, China lw16-40.5 series sf6 circuit breaker manufacturers, suppliers, factory, LW16 40 5 Series SF6 Circuit Breaker, LW24 40 5 Series High Voltage SF6 Circuit Breaker, LW3 12 Secondary Integrated SF6 Circuit Breaker, LW30 72 5 Series High Voltage SF6 Circuit Breaker, LW35 126 Series Outdoor High Voltage SF6 Circuit Breaker, LW9 72 5 Series High Voltage SF6 Circuit Breaker

Send Inquiry