JDC5 JCC5-66kV Series Voltage Transformer
video
JDC5 JCC5-66kV Series Voltage Transformer

JDC5 JCC5-66kV Series Voltage Transformer

Our JDC5/JCC5-66 series voltage transformers feature single-phase, three-winding, cascade-insulation design with fully sealed metal expander construction for reliable voltage measurement and protection in 66kV systems.

• Rated at 66kV with insulation level of 72.5/140/325kV; secondary winding outputs up to 300VA with Class 0.2/0.5/3P accuracy.

• Residual voltage winding rated at 100VA with Class 3P; secondary winding thermal limit output of 2000VA.

• Available in standard, anti-pollution, hot-humid, and high-altitude versions for diverse operating environments.

• Fast delivery, reliable quality, responsive service, and extensive project experience backed by our company.

Product Overview

 

This transformer is of single-phase, three-winding, cascade-insulation type, designed for outdoor installation. It is suitable for use in 50Hz, 66kV non-effectively grounded neutral systems for voltage and energy measurement, as well as relay protection applications. The product features excellent excitation characteristics, reliable operation, and simple maintenance. It is equipped with a metal expander on the top, forming a fully sealed structure.

 

Main Technical Parameters

 

Table 1

Model

Applicable Areas

Creepage Distance to Voltage Ratio

Weight

Mounting Dimensions

Height

Ambient Air
Temperature Variation

Oil
Weight

Total
Weight

Hole Spacing

Number of Holes - Hole Diameter

JDC5-66

For altitudes below 1000m

1.8

2.5

3.1

70

430

337x337

4-Φ18

1470

-30℃~+40℃

JDC5-66W1

For altitudes below 1000m,
polluted conditions

-30℃~+40℃

JDC5-66TH

For altitudes below 1000m,
hot and humid conditions

0℃~+40℃

JDC5-66GY

For altitudes below 2000m

90

180

1700

-30℃~+40℃

 

Table 2

Model

Rated Voltage (kV)

Insulation Level

Rated Output of
Secondary Winding (VA)

Residual Voltage Winding

Secondary Winding Thermal Limit Output (VA)

Primary Winding

Secondary Winding

Residual Voltage Winding

Highest Voltage for Equipment / Power Frequency / Impulse

Class
0.2

Class
0.5

Class
3P

Rated Output (VA)

Accuracy Class

JDC5-66

66000
/ √3

100
/ √3

100
/ √3

72.5/140/325

150

250

300

100

3P

2000

JDC5-66W1

JDC5-66TH

JDC5-66GY

 

Hot Tags: jdc5 jcc5-66kv series voltage transformer, China jdc5 jcc5-66kv series voltage transformer manufacturers, suppliers, factory, JDC5 JCC5 66kV Series Voltage Transformer, JDCF 110 Series Voltage Transformer, JDCF 66W Series 72 5kV Voltage Transformer, JDCF JDC5 220kV Series Voltage Transformer, TYD35 Series 35 220kV Multi Voltage Capacitive Voltage Transformer, voltage transformer vt or pt

Send Inquiry